Want to know more? Get a Quote

1
Yes
None
1
1000000
/other/
Thumbnail

Categories:

Fertility
HCG Pregnancy Test (Midstream)
HCG Pregnancy Test (Midstream) Image

Accessories:

Instruction for use

Principle of Test:

Immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 %

INTENDED USE

HCG Pregnancy Test is a self-testing immunoassay made for the rapid, visual and qualitative determination of human chorionic gonadotropin (HCG) in urine specimen to aid in the early detection of pregnancy.

TEST PROCEDURE

1. Bring the pouched test midstream to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test midstream from the sealed pouch.
3. Remove the Cap and turn around the midstream to show the Absorbent Tip.
4. Hold the midstream by the Thumb Grip with the exposed absorbent tip pointing downward. Urinate on the absorbent tip directly till it is thoroughly wet (at least 5 seconds).
NOTE: Be careful and do not urinate in the Show Window.
5. Re-cap the test midstream and lay it on a flat surface with window side up .
6. Wait for pink-colored lines to appear. Read results within 5 minutes. Do not read results after 5 minutes.

INTERPRETATION OF RESULTS

PREGNANT: Two distinct pink-colored lines appear, one in the test region (T) and one in the control region(C).

NOTE: The intensity of the pink color in the test region (T) may vary depending on the concentration of HCG present in the specimen. Therefore, any shade of pink color in the test region (T) should be considered positive.

NOT PREGNANT: Only one pink-colored line appears in the control region(C). No apparent pink line appears in the test region (T).

INVALID: Control Line fails to appear.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test midstream. If the problem persists, please contact your local distributor.

HCG Pregnancy Test ( Strip)
HCG Pregnancy Test ( Strip) Image

Principle of Test:

immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 %

INTENDED USE:

HCG Pregnancy Test is a self-testing immunoassay made for the rapid, visual and qualitative determination of human chorionic gonadotropin (HCG) in urine specimen to aid in the early detection of pregnancy.

TEST PROCEDURE

1. Bring the pouched test strip to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test strip from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Immerse the test strip in the urine specimen for at least 5 seconds with the arrow end pointing toward the urine. Do not immerse the strip above the printed MAX line.
4. Remove the test strip from the urine and lay flat on a non-absorptive clean surface. Or leave the test strip in the urine specimen as long as the strip is not immersed above the MAX line.
5. Wait for pink-colored lines to appear. Read results within 5 minutes. Do not read results after 5 minutes.

INTERPRETATION OF RESULTS

PREGNANT: Two distinct pink-colored lines appear, one in the test region (T) and one in the control region(C).
NOTE: The intensity of the pink color in the test region (T) may vary depending on the concentration of HCG
present in the specimen. Therefore, any shade of pink color in the test region (T) should be considered positive.
NOT PREGNANT: Only one pink-colored line appears in the control region(C). No apparent pink line appears in
the test region (T).
INVALID: Control Line  fails to appear.
NOTE:Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control
line failure.Review the procedure and repeat the test with a new test strip. If the problem persists, please
contact your local distributor.

HCG Pregnancy Test (Cassette)
HCG Pregnancy Test (Cassette) Image

Accessories:

Instruction for use, urine cup

Principle of Test:

immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 %

INTENDED USE

HCG Pregnancy Test is a self-testing immunoassay made for the rapid, visual and qualitative determination of human chorionic gonadotropin (HCG) in urine specimen to aid in the early detection of pregnancy.

TEST PROCEDURE

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Use the provided pipette to withdraw urine specimen from the urine cup and dispense 3 drops into the sample well.
4. Wait for pink-colored lines to appear. Read results within 5 minutes. Do not read results after 5 minutes.

INTERPRETATION OF RESULTS

PREGNANT: Two distinct pink-colored lines appear, one in the test region (T) and one in the control region(C).

NOTE: The intensity of the pink color in the test region (T) may vary depending on the concentration of HCG present in the specimen. Therefore, any shade of pink color in the test region (T) should be considered positive.

NOT PREGNANT: Only one pink-colored line appears in the control region(C). No apparent pink line appears in the test region (T).

INVALID: Control Line fails to appear.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, please contact your local distributor.

 

 

HCG Pregnancy Test Serum/Urine( Strip)
HCG Pregnancy Test Serum/Urine( Strip) Image

Principle of Test:

immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 %

INTENDED USE:

HCG Pregnancy Test is a self-testing immunoassay made for the rapid, visual and qualitative determination of human chorionic gonadotropin (HCG) in serum/urine specimen to aid in the early detection of pregnancy.

TEST PROCEDURE

1. Bring the pouched test strip to room temperature (15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test strip from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Immerse the test strip in the urine specimen for at least 5 seconds with the arrow end pointing toward the urine. Do not immerse the strip above the printed MAX line.
4. Remove the test strip from the urine and lay flat on a non-absorptive clean surface. Or leave the test strip in the urine specimen as long as the strip is not immersed above the MAX line.
5. Wait for pink-colored lines to appear. Read results within 5 minutes. Do not read results after 5 minutes.

INTERPRETATION OF RESULTS

PREGNANT: Two distinct pink-colored lines appear, one in the test region (T) and one in the control region(C).

NOTE: The intensity of the pink color in the test region (T) may vary depending on the concentration of HCG present in the specimen. Therefore, any shade of pink color in the test region (T) should be considered positive.

NOT PREGNANT: Only one pink-colored line appears in the control region(C). No apparent pink line appears in the test region (T).

INVALID: Control Line  fails to appear.

NOTE:Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.Review the procedure and repeat the test with a new test strip. If the problem persists, please contact your local distributor.

HCG Pregnancy Test Serum/Urine( Cassette)
HCG Pregnancy Test Serum/Urine( Cassette) Image

Accessories:

Instruction for use, pipette

Principle of Test:

immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 %

INTENDED USE:

HCG Pregnancy Test is a self-testing immunoassay made for the rapid, visual and qualitative determination of human chorionic gonadotropin (HCG) in serum/urine specimen to aid in the early detection of pregnancy.

Test Procedure

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.
3. For serum specimen, use the provided pipette to draw and dispense 2-3 drops of specimen into the sample well.
For urine specimen, use the provided pipette to draw and dispense 3 drops of specimen into the sample well.
4. Wait for pink-colored lines to appear. Read results within 5-8minutes. Do not read results after 10 minutes.

INTERPRETATION OF RESULTS

PREGNANT: Two distinct pink-colored lines appear, one in the test region (T) and one in the control region(C).
NOTE: The intensity of the pink color in the test region (T) may vary depending on the concentration of HCG present in the specimen. Therefore, any shade of pink color in the test region (T) should be considered positive.

NOT PREGNANT: Only one pink-colored line appears in the control region(C). No apparent pink line appears in the test region (T).

INVALID: Control Line  fails to appear.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.Review the procedure and repeat the test with a new test strip. If the problem persists, please contact your local distributor.

(LH) One Step Ovulation Test (Midstream)
(LH) One Step Ovulation Test (Midstream) Image

Accessories:

Instruction for use

Principle of Test:

Immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml   Accuracy: >99.5%

INTENDED USE:

LH Ovulation Test is a complete system to help predict the time of ovulation and peak fertility.
It is during this fertile time that pregnancy is most likely to occur. The LH Ovulation Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-48 hours.

TEST PROCEDURE

1. Bring the pouched test midstream to room temperature (15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test midstream from the sealed pouch.
3. Remove the Cap to expose the Absorbent Tip.
4. Hold the midstream by the Thumb Grip with the exposed Absorbent Tip pointing downward. Urinate on the absorbent tip till it is thoroughly wet (at least 5 seconds).

NOTE: Be careful and do not urinate in the Show Window.
5. Re-cap the test midstream and wait for pink-colored lines to appear. Read result within 3-8 minutes. Do not read result after 10 minutes.

INTERPRETATION OF RESULTS

LH Surge: If two pink- colored lines are visible and the test line (T) is equal or darker than the control line(C), You will probably ovulate in the next 24-48 hours. If you want to be pregnant, the best time to have intercourse is after 24 hours but before 48 hours.

No LH Surge: Only control line(C) appears or the test line (T) is present but lighter in color intensity than the control line. This indicates that no LH surge has been detected and you should continue daily testing.

Invalid: No line appears in the control region.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, please contact your local distributor.

(LH) One Step Ovulation Test (Strip)
(LH) One Step Ovulation Test (Strip) Image

Accessories:

Instruction for use

Principle of Test:

Immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml   Accuracy: >99.5%

INTENDED USE:

LH Ovulation Test is a complete system to help predict the time of ovulation and peak fertility.
It is during this fertile time that pregnancy is most likely to occur. The LH Ovulation Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-48 hours.

TEST PROCEDURE

1. Bring the pouched test strip to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test strip from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Immerse the test strip in the urine specimen for at least 5 seconds with the arrow end pointing toward the urine. Do not immerse the strip above the printed MAX line.
4. Remove the test strip from the urine and lay flat on a non-absorptive clean surface. Or leave the test strip in the urine specimen as long as the strip is not immersed above the MAX line.
5. Wait for pink-colored lines to appear. Read result within 3-8 minutes. Do not read result after 10 minutes.

NOTE: Be careful and do not urinate in the Show Window.
5. Re-cap the test midstream and wait for pink-colored lines to appear. Read result within 3-8 minutes. Do not read result after 10 minutes.

INTERPRETATION OF RESULTS

LH Surge: If two pink- colored lines are visible and the test line (T) is equal or darker than the control line(C), the will probably ovulate in the next 24-48 hours. If you want to be pregnant, the best time to have intercourse is after 24 hours but before 48 hours.

No LH Surge: Only control line(C) appears or the test line (T) is present but lighter in color intensity than the control line. This indicates that no LH surge has been detected and you should continue daily testing.

Invalid: No line appears in the control region.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, please contact your local distributor.

(LH) One Step Ovulation Test (Cassette)
(LH) One Step Ovulation Test (Cassette) Image

Accessories:

Instruction for use, pipette

Principle of Test:

Immunochromatographic assay

Product Performance:

Sensitivity: 25mIU/ml   Accuracy: >99.5%

INTENDED USE:

LH Ovulation Test is a complete system to help predict the time of ovulation and peak fertility.
It is during this fertile time that pregnancy is most likely to occur. The LH Ovulation Test detects the LH surge in urine, signaling that ovulation is likely to occur in the next 24-48 hours.

TEST PROCEDURE

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Use the provided pipette to withdraw urine specimen from the urine cup and dispense 3 drops into the sample well.
4. Wait for pink-colored lines to appear. Read result within 3-8 minutes. Do not read result after 10 minutes.

INTERPRETATION OF RESULTS

LH Surge: If two pink- colored lines are visible and the test line (T) is equal or darker than the control line(C), You will probably ovulate in the next 24-48 hours. If you want to be pregnant, the best time to have intercourse is after 24 hours but before 48 hours.

No LH Surge: Only control line(C) appears or the test line (T) is present but lighter in color intensity than the control line.This indicates that no LH surge has been detected and you should continue daily testing.

Invalid: No line appears in the control region.

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, please contact your local distributor.

One Step follicle-stimulating hormone Test
One Step follicle-stimulating hormone Test Image

FSH Test is used to detect FSH in the urine, this helps to check the function of the pituitary gland and check if hormone levels are normal. The test can be used to see if a woman has started the menopause. The test may also be used(along with other tests) to test for possible causes of both male and female infertility.

Fertility
HCG Pregnancy Test (Midstream) Image
HCG Pregnancy Test (Midstream)
Accessories: Instruction for use Principle of Test: Immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >... Read More
HCG Pregnancy Test ( Strip) Image
HCG Pregnancy Test ( Strip)
Principle of Test: immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 % ... Read More
HCG Pregnancy Test (Cassette) Image
HCG Pregnancy Test (Cassette)
Accessories: Instruction for use, urine cup Principle of Test: immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml  10mIU/ml  Accu... Read More
HCG Pregnancy Test Serum/Urine( Strip) Image
HCG Pregnancy Test Serum/Urine( Strip)
Principle of Test: immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml  10mIU/ml  Accuracy: >99.5 % ... Read More
HCG Pregnancy Test Serum/Urine( Cassette) Image
HCG Pregnancy Test Serum/Urine( Cassette)
Accessories: Instruction for use, pipette Principle of Test: immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml  10mIU/ml  Accura... Read More
(LH) One Step Ovulation Test (Midstream) Image
(LH) One Step Ovulation Test (Midstream)
Accessories: Instruction for use Principle of Test: Immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml   Accuracy: >99.5% ... Read More
(LH) One Step Ovulation Test (Strip) Image
(LH) One Step Ovulation Test (Strip)
Accessories: Instruction for use Principle of Test: Immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml   Accuracy: >99.5% ... Read More
(LH) One Step Ovulation Test (Cassette) Image
(LH) One Step Ovulation Test (Cassette)
Accessories: Instruction for use, pipette Principle of Test: Immunochromatographic assay Product Performance: Sensitivity: 25mIU/ml   Accuracy: >9... Read More
One Step follicle-stimulating hormone Test Image
One Step follicle-stimulating hormone Test
FSH Test is used to detect FSH in the urine, this helps to check the function of the pituitary gland and check if hormone levels are normal. The test can be used to see if a woman has started the menopause. The test may also be used(alon... Read More